Code Error Mesin Fotocopy Canon
E code Description Category Remarks
E000 The
fixing temperature does not go up after turning ON the power due to a fault in
the thermistor or the heater, etc.,
(e.g. It does not reach 70°C degrees within 2 min.) Related fixing unit
E001 The
fixing temperature abnormally goes up due to a fault in the thermistor or SSR,
etc.
E002 The
fixing temperature does not reach a specific temperature due to a fault in the
thermistor or the heater, etc.
e.g) The fixing temperature does not go up to 190°C degrees within 5
min after reaching 70°C degrees.
E003 The
fixing temperature drops abnormally after wait time is up due to a fault in the
thermistor, the heater, etc. (e.g. After wait time is up, the fixing
temperature drops to 70°C degrees).
E004 A short circuit in the fixing heater drive circuit
(SSR, etc) is detected.
E005 The fixing web is wound up completely.
E006 The
fixing drawer connector is not connected as the front door is closed.
E007 The fixing film is off to the side.
E008 A
specific number of copies are made after the machine detects that fixing oil is
out. Since a user cannot re-supply
fixing oil, the error code is indicated.
E009 The
rated voltages of the power supply and the fixing unit do not match.
E010 Clock
pulses fail to be generated or the PLL lock fails to be released due to a fault
in the main motor, etc. Related
drum drive unit and main drive unit
E011 Excess
current flows to the motor control circuit because the main motor is locked up,
etc.
E012 Clock
pulses fail to be generated or the PLL lock is released due to a fault in the
drum motor, etc. In case the
drum drive motor exists in addition to the main motor, this code refers to an
error of a motor which drives mainly other units than the drum.
E013 •The PLL lock is released because waste
toner motor is locked up, etc.
•The micro switch employed to detect clogging of waste toner is
activated.
•The waste toner case is detected full.
E014 •The PLL lock of the fixing/feeding motor is
released.
•Excess current of the feeding motor is detected.
E015 •Clock
pulses of the pick-up/duplexing/developing motor fails to be generated or be
detected.
•Excess current of the pick-up/duplexing/developing motor is
detected.
E016 Excess
current of the reciprocating motor of the photosensitive drum cleaner unit is
detected.
E017 The PLL lock of the drive motor of the
holding tray unit is released.
E018 The PLL lock of the drive motor of the oil
removing roller is released.
E019 The waste toner case is detected full
although it is not.
E020 The
developer fails to be replenished with starter developer properly.Related
developing unit A hopper motor
error is identified by the detail code of E020. However, it may be identified
by E02x according to need.
E021 The
rotor fails to rotate and move properly due to a fault in the developing
rotor/motor ass'y.
E022 Pressure
fails to be applied to the developer after a specific time passes after the
developer is selected.
E023 The developer sleeve motor fails to rotate
properly.
E024 The developer cannot be detected. ( not
mounted properly.)
E025 Excess
current of the toner delivery motor or the cartridge motor is detected.
E030 The total counters are not functioning. Related counter
E031 The optional counters are not functioning.
E032 The
counters for ASSIST are not functioning. (Disconnection of counter pulse for
ASSIST.)
E040 The
lifter position signal fails to be generated due to a lifter clutch failure. Related paper pick-up unit
E041 The paper deck lifter fails to be detected
within a specific time.
E042 The roll
paper cutting operation is not functioning properly because the cut motor does
not work, etc.
E043 An
abnormal signal is detected due to a fault in the pick-up motor for the 3-cassette
deck/3.5K paper deck.
E050 A
malfunction of the holding tray. A fault in the side registration is included. Related duplex unit The duplexing unit for the stack system
E051 The home
position of the side registration cannot be detected within a specific time. The duplexing unit for the
through-path system
E054 The home
position of the duplexing unit feed roller cannot be detected.
E055 The
horizontal registration guide of the duplex unit exceeds its maximum travel
distance.
E060 The home
position of the primary corona wire cleaner cannot be detected within a
specific time. Relateted charging
E061 Specific
potential is not be required or the limiter is activated as the potential is
controlled.
E062 The
photosensitive drum temperature does not reach a specific value due to a fault
in the photosensitive drum heater, etc.
E063 The home
position of the transfer corona wire cleaner cannot be detected. An error code is not to be indicated.
E064 The
setting value for the output from the microcomputer considerably deviates from
the control value of the actual output.
E065 High voltage leakage from the primary corona
assembly is detected.
E066 Signals from the temperature/humidity sensor
cannot be detected.
E067 Two or
more faults in the primary/ pre (post)-transfer/ transfer/ separation high
voltage are detected (including power output stoppage, electric leakage from
the primary corona assembly).
E068 High
voltage leakage from or an open circuit in the separation corona assembly is
detected.
E069 High
voltage leakage from or an open circuit in the transfer corona assembly is
detected.
E070 The home
position of the transfer drum cannot be detected within a specific time. Related transfer
E071 An image
leading edge signal cannot be detected within a specific time.
E072 A fault in the main motors such as the
transfer drum motor, etc.
E073 The
transfer drawer connector or the transfer frame drawer connector is not
connected as the front door is closed.
E074 The
transfer belt unit does not reach the target position within a specific time.
E075 The transfer belt is off to the side.
E076 The transfer belt web is wound up
completely.
E077 The motor inside the transfer belt unit has
a fault.
E079 The home
position (to apply pressure) of the transfer drum cleaner unit cannot be
detected.
E080 An error
occurs in the communication with the multi color unit controller PCB. Related developing unit for multi color
unit
E081 The vertical motor clock is faulty.
E082 The horizontal motor clock is faulty.
E083 The CD unit horizontal movement right sensor
is faulty.
E084 The CD
unit horizontal movement left sensor is faulty.
E085 The CD
unit feeder release sensor is faulty.
E086 The CD
unit claw release is faulty.
E089 A
malfunction of the multi color unit.
E090 The
document feed motor is not functioning properly. related document feeder (bulit-into machine)
E091 A
failure in the detection of the document feed sensor.
E100 The BD
signal cannot be detected within a specific time. Related laser
E101 The AF
motor of the laser unit is faulty.
E102 The
light intensity of the laser does not reach a specific level.
E110 The
polygonal scanner motor does not reach a specific speed within a specific time. Related laser scnner
E111 The
polygonal cooling fan does not rotate properly.
E120 The
temperature of the laser does not reach a specific value.Related laser
temperature control
E121 The
stoppage of the laser cooling fan is detected.
E140 The
movable guide motor is turned ON, and a specific position cannot be detected
within a specific time. Related
BJ
E141 1. The
capping motor is turned ON, and a specific position cannot be detected within a
specific time.
2. A specific position of the cam sensor for the recovery system
cannot be detected within a specific time.
E142 The
pressure position switching motor is turned ON, and a specific position cannot
be detected within a specific time.
E143 The
intake switching motor is turned ON, and a specific position cannot be detected
within a specific time.
E144 A detection
signal is not returned to the ink pump monitor after the ink pump is activated:
DCC -> BHD -> pump drive signal
E145 No
signal is generated from the position sensor within a specific time after a
drive signal of the cutter motor is generated.
E146 1. The
waste ink full sensor is turned ON.
2. The intake counter for waste ink exceeds a specific value.
E150 Neither
thermistor nor trimmer resistance is connected to the head. (The head is not
connected.) Related BJ head
E151 The
thermistor of the head is open-circuited.
E152 The
thermistor of the head is short-circuited.
E153 The
trimmer resistance of the head is open-circuited.
E154 The
trimmer resistance of the head is short-circuited.
E155 The
trimmer resistance of the head is out of specifications.
E156 When a
specific voltage is applied to the head, the voltage of the head is not changed
within a specific time.
E157 The
voltage of the head is out of the specifications.
E160 The
temperature of the head does not reach a specific temperature within a specific
time. Related BJ head temperature control
E161 The
temperature of the head exceeds a specific temperature.
E170 When the
pulse motor for the head scan is driven, it cannot be detected by a sensor
within a specific time. Related
BJ head scanner
E171 The
motor is not connected to the pulse motor driver PCB for the head scan.
E172 The gate
array employed to drive the pulse motor for head scan is faulty.
E180 The
motor is not connected to the vertical scanning pulse motor driver PCB. Related BJ paper feed
E181 The gate
array employed to drive the vertical scanning pulse motor is faulty.
E182 After
the vertical scanning motor is driven, the phase sensor cannot be detected
within a specific time.
E183 After
the registration roller cam clutch 2 is turned ON, a given paper size cannot be
detected within a specific time.
E190 RAM
directly connected to CPU is faulty. Related
CPU (printer unit) Failures in RAM of
the laser controller are indicated with detail codes.
E191 An error
occurs in the communication with the microcomputer (D/A converter) for high
voltage use. Machines which do
not have detail code function may use this code.
E192 An error
occurs in the communication with A/D converter.
E193 The gate
array is faulty.
E194 The auto
registration is faulty.
Data from the # pattern reading CCD is invalid.
E195 ROM
failure -> No. of times data is written on EEPROM reaches the upper limit.
E196 EEPROM
failure: EEPROM read and write error (except software counter), an error in
EEPROM areas on DIMM.
E197 An error
occurs in the communication within the printer:
•Errors continuously occur in the communication within the printer.
•Interruption during receiving is not made within a specific time.
E198 An error
occurs in IC on the DC controller.
yang mau tanya silahkan